Speck NTA AE 10-50/240 drinking water separation station 561.1005.230

    9,010.98 € 9,010.98 € 9010.98 EUR

    9,010.98 €

    Option not available

    Diese Kombination existiert nicht.

    Add to cart

    Flow rate series: Q up to max. 13 m³/h | Delivery head series: H up to max. 250 m | Fluid temperature series: t up to max. 20 °C | Operating pressure series: p up to max. 25 bar | Drive insulation class: F | Drive voltage: 3~ 230/400 V ± 10 %


    In the profluid store simply buy online - for larger orders or scale discounts please contact us for an individual offer.
     
    The offer is exclusively for professionals. 

    Speck NTA AE 10-50/240 drinking water separation station 561.1005.230


    Partnumber :561.1005.230


    Bacon drinking water separation station 561.1005.230 NTA AE 10-50/240

    Drinking water separation stations prevent the medium from flowing back from service water lines connected behind it into the drinking water line and are used in fire extinguishing systems, sprinkler systems, laboratory water systems and in agriculture. As a manufacturer of drinking water separation stations, SPECK guarantees hygiene by separating the drinking and service water using a pre-tank, which generally has a DVGW certificate for safe connection in accordance with W 540 and is also tested by DEKRA in the area of ​​fire-fighting water systems. Our systems offer comfort with motorized ball valves, which prevent pressure surges in the lines by opening and closing as required, and can also easily comply with the specifications for flushing according to the latest DIN 1988 Part 600 with flow rates of max. 2 m/sec. In extinguishing water systems according to DIN 14462, flushing takes place once a week according to DIN 1988-600. In the case of drinking water separation stations for the water supply, this takes place at the latest every 72 hours according to VDI 6023. In both cases with safety devices according to DIN EN 1717 type AB, with a free outlet and a controlled emergency overflow to protect the drinking water, with the aim of maximum safety to guarantee. For this purpose, systems are used that are tailored to the entire system down to the smallest detail, for a long service life of your drinking water separation station. To control the system, we have developed a simple but well thought-out principle based on decades of experience. All information can easily be called up via the display. By installing standardized branded products as part of the control, it can be easily repaired anywhere in the world. That saves time and money. We guarantee a 100% final test for every drinking water separation station. All products go through a standardized testing process that is documented for our customers. This ensures that the commissioning of Speck drinking water separation stations will be a complete success.

    Application


    Extinguishing water supply, mains disconnection, sprinkling, water supply

    Tech. Details

    Technical details
    Flow rate series Q up to max. 13 m³/h
    Head of series
    H up to max. 250 m
    Media temperature series
    t up to max. 20 °C
    Operating print series
    p up to max. 25 bar
    Inlet pressure (recommended)
    p min. 1 bar to max. 6 bar
    Funding medium
    Clear liquids chemically affecting the equipment materials and do not attack mechanically.
    Drive Protection
    IP 55
    Drive insulation class
    F
    Drive Voltage
    3~ 230/400 V ± 10 %
    Drive speed
    2850 rpm
    Drive frequency
    50 Hz
    Type code
    NTA : : : : .System type ADefault EFrequency controlled (FU engine integrated) H .Frequency converter type (FU control cabinet 15.pump size 70.Step number x 10 700: : : : .Pre-tank dimension
    Rated current (A) 3~ 400V
    4,6
    Rated current (A) 1~ 230V
    N/A
    Weight approx. (kg)
    98
    Type suction port (Rp)
    1
    Print port (Rp)
    1 ½
    Flow rate (m³/h) Average flow rate (m³/h)
    8
    Operating pressure normal/max. (bar)
    4,6
    Power consumption min - max (W)
    N/A
    Power output P2
    2,2
    Boiler
    N/A
    Material pump housing
    Stainless steel 1.4301
    Material wheels
    Stainless steel 1.4301
    Material O-rings
    EPDM
    Material pump shaft
    Stainless steel 1.4305
    Mechanical seal material
    Carbon/SiC/EPDM
    Material fittings
    Copper Alloy
    Piping material
    Stainless steel 1.4571
    Material base frame
    N/A
    Material storage container
    PE
    Solenoid valve material
    Brass
    Ball valve material
    Stainless steel 1.4408

    Execution



    The plants are equipped with a 700 liter pressureless reservoir running. The compact construction ensures space-saving installation. A safe one Drinking water separation is achieved through hygiene compliance according to VDI 6023 and safety devices according to EN guaranteed in 1717. Easy connection to that Drinking water network, as well as the fully automatic function of an im Scope of delivery included (frequency-controlled at NTA AE) Pressure boosting system, round off a compact, ready-to-connect and user-friendly drinking water separation station.